En el transcurso de una semana, para una unidad Seagate de 3 TB (ST3000DM001-1CH166), smartd informó un número cada vez mayor de sectores fuera de línea no corregibles y actualmente ilegibles (pendientes), luego un número decreciente, hasta que finalmente el recuento fue 0 y la condición de error Reiniciar. De los registros (que muestran solo los cambios):
Jul 6 18:04:57 x smartd[462]: Device: /dev/sdb [SAT], 8 Currently unreadable (pending) sectors
Jul 6 18:04:58 x smartd[462]: Device: /dev/sdb [SAT], 8 Offline uncorrectable sectors
[...]
Jul 7 16:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors (changed +8)
Jul 7 16:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors (changed +8)
[...]
Jul 11 14:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Currently unreadable (pending) sectors (changed +8)
Jul 11 14:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Offline uncorrectable sectors (changed +8)
Jul 11 14:34:57 x smartd[462]: Device: /dev/sdb [SAT], 32 Currently unreadable (pending) sectors (changed +8)
Jul 11 14:34:58 x smartd[462]: Device: /dev/sdb [SAT], 32 Offline uncorrectable sectors (changed +8)
[...]
Jul 13 09:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Currently unreadable (pending) sectors (changed -8)
Jul 13 09:04:57 x smartd[462]: Device: /dev/sdb [SAT], 24 Offline uncorrectable sectors (changed -8)
Jul 13 09:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors (changed -8)
Jul 13 09:34:58 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors (changed -8)
Jul 13 10:04:57 x smartd[462]: Device: /dev/sdb [SAT], 16 Currently unreadable (pending) sectors
Jul 13 10:04:57 x smartd[462]: Device: /dev/sdb [SAT], 16 Offline uncorrectable sectors
Jul 13 10:34:57 x smartd[462]: Device: /dev/sdb [SAT], No more Currently unreadable (pending) sectors, warning condition reset after 1 email
Jul 13 10:34:57 x smartd[462]: Device: /dev/sdb [SAT], No more Offline uncorrectable sectors, warning condition reset after 1 email
Además, el recuento de sectores reasignados también es 0, por lo que los sectores no parecen haber sido reasignados. Aquí está la smartctl -a
salida completa (actual) para la unidad:
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.14.4-100.fc19.x86_64] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST3000DM001-1CH166
Serial Number: W1F30FK2
LU WWN Device Id: 5 000c50 06129a9a8
Firmware Version: CC27
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Jul 16 11:23:08 2014 EDT
==> WARNING: A firmware update for this drive may be available,
see the following Seagate web pages:
http://knowledge.seagate.com/articles/en_US/FAQ/207931en
http://knowledge.seagate.com/articles/en_US/FAQ/223651en
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 584) seconds.
Offline data collection
capabilities: (0x73) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 347) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x3085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 115 099 006 Pre-fail Always - 91131424
3 Spin_Up_Time 0x0003 094 094 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 12
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 078 060 030 Pre-fail Always - 59138260
9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 5888
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 12
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 0 0
189 High_Fly_Writes 0x003a 097 097 000 Old_age Always - 3
190 Airflow_Temperature_Cel 0x0022 053 049 045 Old_age Always - 47 (Min/Max 23/51)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 10
193 Load_Cycle_Count 0x0032 096 096 000 Old_age Always - 8086
194 Temperature_Celsius 0x0022 047 051 000 Old_age Always - 47 (0 22 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 5703h+56m+25.808s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 11838196191
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 211237637103
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
He descargado pero todavía no ejecuto Seatools en la unidad, pero el estado SMART actual de la unidad básicamente parece estar bien. ¿Qué podría causar tal comportamiento?
ACTUALIZACIÓN: Para futuros lectores, el disco estuvo realmente bien durante un par de meses más, momento en el que más sectores se vuelven incorregibles / fuera de línea, y el número de sectores reasignados comenzó a aumentar más allá de 0, y la autocomprobación larga SMART comenzó a fallar con una lectura error. Así que estos mensajes parecían ser una advertencia temprana útil.
Respuestas:
He tenido esto varias veces recientemente con un firmware CC24 Seagate ST3000DM001-1CH166 similar. No necesita Seatools, solo ejecute una prueba inteligente larga:
Entonces, si smarctl no muestra ningún error, estás bien por ahora:
Si falla, envíe directamente a Seagate. Reemplazaron mi último fallido en aproximadamente una semana.
fuente
El sector pendiente actual es solo eso, la cantidad de ubicaciones que el disco conoce sobre eso necesita ser reasignada, pero aún no se ha reasignado ya que el disco no tiene una fuente para la reasignación de datos. Una vez que escriba en esa ubicación, el disco reasignará automáticamente el área a otro lugar y escribirá los nuevos datos en el nuevo lugar y disminuirá el límite del sector pendiente actual.
Todo esto está perfectamente bien y cómo debería funcionar el disco.
Puede usar diskscan en Linux o HD Tune en Windows para escanear el disco en busca de ubicaciones incorrectas y también intentar "arreglar" las ubicaciones haciendo que el software las escriba para intentar la reasignación inmediata.
fuente
sudo apt-get install diskscan
. (Supongo que eres el autor de ambas versiones.)